Creating new custom metadata records and keeping older backups

Renaming a Component Configuration record (for example to BACKUP) does not take it out of use. The Clock app picks its configuration by Type, not by label or developer name.

How the Clock app chooses its configuration

The Clock app uses the b3s__Component_Configuration__mdt record whose Type is Clock In / Out Component. Keep exactly one record with that Type. If more than one record has it, there is no guarantee which one the app loads.

Keep a backup copy

  1. Clone the current record and make your changes on the new copy.
  2. On the old copy, rename it if that helps you find it later, and change Type to None (or any value that is not Clock In / Out Component).
  3. Check that only the new record has Type Clock In / Out Component.

None is not a special backup status. It simply means no app selects the record. To restore the backup, set its Type back to Clock In / Out Component and change the other record's Type to None.

The same approach works for the other component-configured apps: keep one active record per Type and move copies to None.

See the Clock app and the App definition JSON reference for the configuration itself.